8. T
ROUBLE
S
HOOTING
No Indicators are on
Check mains power.
Power LED (top) is off but other LED indicators are on
Possible adapter fault.
Power Line Communications LED (middle) is off
This is normal for the first adapter installed. Its LED should come on when a
subsequent adapter is added to the network.
Check that the Network Name has been correctly set. Adapters with different
Network Names will not communicate with each other. Check for a common
Network Name by plugging the adapters in adjacent or near adjacent power points.
If PLC LED indicator lights then a common Network Name has been set.
If after confirming the Network Name the adapters are moved back into position but
the PLC LED remains off, then ensure that the adapters have been plugged directly
into a wall mounted power point. Failing resolution, it is possible that the mains
wiring at the required locations may be unsuitable, please try again using different
power points.
Ethernet LED (bottom) is off
Check the Ethernet connection.
All LEDS are on or blinking but the attached devices are not communication.
When all three LEDS being are on or blinking the PowerLine 85 network has been
established and operational. At this stage you will need to check the configuration of
the attached Ethernet devices to ensure that they are correctly configured.
Generally, if two pieces of Ethernet equipment can communication with each other
over standard Ethernet cabling then they are correctly configured for use in a
PowerLine 85 network.
Comentarios a estos manuales